How to Measure Your Front Door Step for a Ramp

How to Measure Your Front Door Step for a Ramp

To measure your front door step for a ramp, take three numbers in millimetres: the outside rise (ground to the top of the sill), the inside rise (floor to the top of the sill) and the sill depth (front edge to back edge). Measure from the surface the ramp will actually rest on, then check which way the door opens and how wide the usable gap is, and you'll have everything you need to choose a ramp type.

By Pact Home Access · 20 November 2026

It takes about 10 minutes. Write each number on the printable sheet near the end of this guide as you go.

What you need

  • A steel tape measure marked in millimetres
  • A spirit level or straight edge, ideally 600mm or longer
  • Your phone, to photograph each measurement with the tape in shot
  • A pen and the measuring sheet
  • A helper, if you can, to hold the level while you read the tape
Tape measure, notepad, pen and phone laid out on a concrete front doorstep below a white uPVC door.
Illustration: everything you need to measure your step.

The three measurements

1. Outside rise

This is the height from the ground outside to the highest point of the door sill. It decides how long the outside ramp needs to be.

  1. Rest the spirit level on the top of the sill so it sticks out over the step, and check it's level.
  2. Measure straight down from the underside of the level to the ground directly below the sill edge.
  3. Do this at the left and right of the doorway. Write down both numbers; if they differ, use the higher one.
Spirit level resting on a white uPVC door sill over a concrete step, with a tape measure between the path and the level.
Illustration: measuring the outside rise from the path to the top of the sill.

2. Inside rise

This is the height from the floor inside to the highest point of the same sill. Many doors have a smaller step on the inside, and some have none.

  1. Take up any doormat first, and measure to the finished floor surface (carpet, laminate or tiles).
  2. Measure from the floor to the top of the sill, at the left and right of the doorway.
  3. Write down the higher number. If it's zero, write 0.
Inside view of an open front door with a spirit level and tape measure at the threshold, measuring up from the laminate hall floor.
Illustration: measuring the inside rise with the doormat moved.

3. Sill depth

This is the front-to-back depth of the sill at the top. It matters for bridge-style threshold ramps that span the sill, and for knowing what a ramp would rest on.

  1. Push the tape's hook against the inside edge of the sill, where it meets the hall floor, and hold the blade straight and level across the sill.
  2. Read the number directly above the sill's outer front edge. On a sloping sill, keep the blade straight rather than letting it follow the slope, and include the whole depth, not just the flat part.
  3. Note what the sill is made of: plastic (uPVC), aluminium, wood or stone.
Overhead view of a tape measure held straight across a white uPVC door sill, from its inside edge to its front edge.
Illustration: hook against the inside edge, read above the outer front edge.

Tip: photograph every measurement with the tape in shot. If you send us your numbers, the photos let us check them.

Where to measure from

Measure from the surface the ramp will rest on, not the edge of the path or the front of a step. Those are often different heights, and a few millimetres matter on a short ramp.

  • There's a step below the door: a ramp usually has to cover the step and the sill together. Measure the total rise from the path to the top of the sill, then measure the step on its own as well.
  • The path slopes away from the door: the rise grows the further out the ramp lands. Hold the level out from the sill along the line the ramp would take, and measure down at roughly where the ramp would end.
  • The ground is uneven or has a drain cover: note it on the sheet, because a ramp needs a firm, flat surface to sit on.
Long spirit level held level from a door sill over a path sloping away from the house, with a tape measure at the far end.
Illustration: on a path that slopes away, measure the gap at roughly where the ramp would end.

uPVC door sills

Most uPVC and composite front doors have a sill with a sloping outer face and a small raised lip, so they need a little more care.

  • Measure to the highest point of the sill, usually the lip just in front of the door, not partway down the slope.
  • Measure the full depth, including the sloping part, as in step 3 above.
  • Don't drill or screw into the sill. It's part of the door's weather seal. Look for a ramp designed to rest on or bridge a uPVC sill instead; our threshold ramps for uPVC doors are chosen for this.
  • For context: guidance for new homes in England aims for a threshold of no more than 15mm, so older doors with a much bigger step are common, and that's exactly where a ramp helps.
Side close-up of a white uPVC door sill's sloping face and raised lip, with a tape measure from the step to the top of the lip.
Illustration: measure to the top of the raised lip, not partway down the slope.

Door swing and usable width

A ramp has to work with the door, not just the step.

  • Which way does the door open? Most UK front doors open inwards. If yours does, an inside ramp must not stop the door opening. Measure the gap between the bottom of the open door and the floor, and how far the door sweeps into the hall.
  • Usable width: with the door fully open, measure from the door stop on the closing side of the frame straight across to the nearest obstruction on the other side, usually the face of the open door or its handle. This is the gap a wheelchair or walker actually passes through, and it's narrower than the door itself.
  • Compare it with the chair or walker: measure the widest point of the wheelchair, scooter or walking frame that will use the ramp, including wheels and hand rims. For comparison, new homes in England are expected to have at least 775mm of clear width at the entrance door; many older doors have less.
  • Space in front of the door: measure straight out from the sill to the nearest obstacle, such as a gate, wall, car or the end of the porch. This is the longest ramp that will fit.
Tape measure stretched across an open uPVC front doorway from the door stop to the open door.
Illustration: usable width runs from the door stop to the nearest point of the open door.

Turning your numbers into a ramp type

The rise tells you how long a ramp needs to be, and the space in front of the door tells you whether it fits. Ramp length is the rise multiplied by the gradient: a 100mm rise at 1:12 needs a ramp about 1,200mm long.

Rise Length at 1:12 Length at 1:15 Length at 1:20
25mm 300mm 375mm 500mm
50mm 600mm 750mm 1,000mm
100mm 1,200mm 1,500mm 2,000mm
150mm 1,800mm 2,250mm 3,000mm
200mm 2,400mm 3,000mm 4,000mm

For comparison, Building Regulations guidance for new buildings treats 1:12 as the steepest gradient for a short ramp of up to 2m, and prefers 1:15 or 1:20 for longer ones. Shallower is easier to push up and easier to control on the way down. The right gradient for you depends on the user, the chair or scooter, and whether someone pushes, so treat the table as a guide.

Then match your numbers to a ramp type:

  • A small step at the sill only, with little or no inside rise: a threshold ramp. See threshold ramps for uPVC doors.
  • A step on both sides of the sill: an inside and outside threshold ramp, or a bridge ramp that spans the sill (this is where sill depth matters).
  • The sill plus one or two steps: a longer portable or modular ramp. See wheelchair ramps for steps.
  • The ramp you need is longer than the space in front of the door: look at a shallower route, a different door or a modular ramp with a turn. An occupational therapist can assess this with you.

Our which ramp guide goes through each option for front doors.

Printable measuring sheet

Download the measuring sheet (PDF): print it, fill it in at the door, and keep it with your photos.

Measurement How Your number
A Outside rise, left Ground to top of sill ______ mm
A Outside rise, right Ground to top of sill ______ mm
B Inside rise Floor to top of sill (mat removed) ______ mm
C Sill depth Inside edge (hall floor) to outer front edge ______ mm
D Usable width Door stop to open door or handle ______ mm
E Space in front of door Sill straight out to nearest obstacle ______ mm
F Widest point of chair or walker Including wheels and hand rims ______ mm
Door opens Inwards / outwards ______
Sill material uPVC / aluminium / wood / stone ______
Path below door Level / slopes away / step ______
Ramp user Manual wheelchair, self-propelled / pushed / powered chair / scooter / walking aid ______

Frequently asked questions

Should I measure in millimetres or inches?

Millimetres. UK ramps are sold by rise and length in millimetres, so measuring in mm avoids conversion mistakes.

What if one side of my step is higher than the other?

Use the higher number, and write both down. A difference of more than a few millimetres can make a fixed ramp rock, so an adjustable ramp, or one with adjustable feet, may suit better.

Can I put a ramp on a uPVC door sill?

Yes, if the ramp is designed to rest on or bridge the sill without being fixed into it. Don't drill or screw into a uPVC sill, because it forms part of the door's weather seal. If in doubt, check with the door's installer.

How steep can a wheelchair ramp be?

It depends on the user and the chair. As a benchmark, Building Regulations guidance for new buildings allows 1:12 only for short ramps of up to 2m, and prefers 1:15 or 1:20 for longer ones. Shallower ramps are easier for everyone.

Do I need to measure inside if the door has no inside step?

Yes, write 0. Knowing there's no inside rise rules out an inside ramp and helps us suggest the right type.

Not sure what your numbers mean?

Send us your measurements and photos through Check my step. We'll tell you which ramp types are worth looking at for your door, free of charge.

Sources

Share